Light intensity is controlled through
the individual lamp switches. In each
Caselite, the first tube is controlled
by the AC switch in the power cable
and remaining lamps are controlled
by the switch(es) on back of fixture.
A To turn the fixture on, Click the
power switch on the AC cable.
This will turn lamp 1 on.
B Operate the switches on the back
of the unit to turn the other lamp(s)
on. By using these switches,
you will be able to control light
intensity level.
The Caselites come with a user-replace-
able mini fuse which is installed in
a small holder on the same plate as the
exterior AC power socket. Access the
fuse by removing the cap with a small
flathead screwdriver. Swap fuse if
necessary and replace holder.
Caselite2 ETL model
uses fuses rated at 3.15 Amps and
250 Volts.
Caselite4 ETL model
uses fuses rated at 5 Amps and
250 Volts.
Voltage Selector
The Caselite has an auto voltage
setting ballast. The Caselite will set
itself automatically from 120 - 240v.
Lamps
The Caselites use compact (55
watt) fluorescent lamps.
GE Cinema-Plus
®
Lamps
(Manufacturer rated lamp life 8,000 hrs)
Better lighting for film (still or motion
picture) due to better color rendering
with film emulsions. May require
“minus green” filtration gel (1/8).
Tungsten CRI °K
FLC55-TU Cine-Plus 55w/ 90+ 3200
Daylight CRI °K
FLC55-DA Cinema-Plus 55w 90+ 5500
Osram Studioline
®
Lamps
(Manufacturer rated lamp life 8,000 hrs)
Designed for use in video & digital
imaging for higher output.
Tungsten CRI °K
FLS-55TU Studioline 55w/3200 85 3200
Daylight CRI °K
FLS-55DA Studioline 55w/5600 85 5600
Lamp Changes
To change a lamp, remove the plastic
eggcrate (if attached) by releasing the
snap-locks on each end. Remove both
metal endplates by turning the twist-
locks (see illus.). Note that the light-
tube sockets are installed on alternating
ends of the fixture. To remove a tube,
gently grasp it by its glass end and
swing it slightly out from the fixture
while pulling it carefully from the sock-
et. Replace lamp in same way, opposite
order. (Be very careful as lamp-tubes
are fragile and can easily shatter. Read
lamp mfr's
Warnings).
3
Caselite
®
Operations
Fuse Change
Lamps & Lamp Changes
Controlling Light Intensity
Caselite 4 Switches
Caselite 2 Switch
Fuse
Vue de la page 2
1 2 3 4

Commentaires sur ces manuels

Pas de commentaire